Agilent 1100系列高效液相色譜系統(tǒng)配置有在線真空脫氣裝置、四元梯度泵、100位自動進樣器、柱恒溫箱、可變波長檢測器(VWD)、二極管陣列(DAD)檢測器
樣品容量:1個100位樣品盤,每個樣品盤可放置100個2-mL樣品瓶
2個 40位樣品盤,每個樣品盤可放置 40個2-mL樣品瓶
2個15位樣品盤,每個樣品盤可放置15個6-mL樣品瓶
樣品殘留:<0.05%(啟動洗針程序)
重復(fù)進樣次數(shù):1~99次/樣品
操作壓力:400bar
L mL,增量為0.1mL;安裝多次進樣組件,進樣體積可達1500m進樣范圍:0.1~100
進樣:< 0.25% RSD(進樣體積 5~100mL)
< 1% RSD (進樣體積1~5mL)
L/min m快進樣速度:1000
樣品粘度范圍:0.2~50cp
pH范圍:1.0~9.5
微克: 生物技術(shù)領(lǐng)域的酶的分離、生物學(xué)和生化學(xué)測試
毫克: 結(jié)構(gòu)描述和特征鑒定,包括:生產(chǎn)中的副產(chǎn)品、生物矩陣的新陳代謝產(chǎn)物、天然產(chǎn)物
克級: 對照品(分析標準)毒物學(xué)分析所需組份:高純品中的主要成份、副產(chǎn)品的分離提取
千克級:工業(yè)規(guī)模生產(chǎn),活性成份,藥物
The Agilent 1100 system is designed to be controlled with a hand-held controller or a computer running ChemStation. It is a modern series of stackable HPLC components.
This Agilent 1100 HPLC can be combined with other system to make up a variety of systems and offers a comprehensive selection of modules that work with other HPLC systems.
One of the features of Agilent 1100 is the online vacuum degasser which offers reduced operating costs which ensures high instrument performance without the need for helium.
The Agilent 1100 has built-in wavelength verification. You can choose from the programmable variable wavelength verification as means for tracking the detector’s performance characteristics. The system was optimized for improved sensitivity which is a part of its new design that allows front access for the exchange of flow cells and lamps that are pre-aligned.
The Hewlett Packard HP / Agilent 1100 HPLC series is the current model and arguably the best design in the industry because of the optimized design of the quaternary pump ensuring virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This design with variable stroke volume allows pulse-free solvent delivery and efficient mixing. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvents and is maintenance free. With high-speed proportioning valve and pre-configured vacuum degasser, for convenient low-pressure mixing of up to four solvents and highest flexibility in solvent choices.
Hewlett Packard HP / Agilent 1100 HPLC Pump Features:
Ease-of-use - handheld control module lets you enter operating parameters fast, store methods easily and display pressure profile, diagnostics and task-oriented information.
Durable - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.
Wide flow range - up to 10 ml/min for broad HPLC work, including semi-preparative separations.
Better for GLP - built-in leak and pressure test with graphical presentation of pressure profiles, and early maintenance feedback.
Hewlett Packard HP / Agilent 1100 HPLC Detectors - VWD or PDA (diode array)
You can add spectral acquisition to your HPLC analyses with the Agilent 1100 Series diode array detector. Verify separation quality with peak purity, multiple signals and spectral libraries - interactively or automatically in the same run as your analytical quantification. Extended wavelength range from 190 to 950 nm with highest sensitivity or spectral resolution with programmable slit. And holmium oxide wavelength verification for GLP compliance. The temperature management system ensures optimum baseline stability-even under rough ambient conditions.
Two lamps in the HP 1100 Series diode-array detector ensure the highest light output from 190 to 950 nm, for the lowest detection limits over the entire wavelength range. The use of 1,024 diodes and an optical slit programmable from 1 to 16 nm ensures the best possible spectral bandwidth.
Both the VWD and diode array detectors use a holmium oxide filter for automated wavelength verification and for tracking the detector's performance characteristics. They also employ a new design that allows front access for the exchange of flow cells and pre-aligned lamps.
Features:
Access the spectral domain with superior 3D optics-simultaneous illumination using combined deuterium and tungsten lamps for highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution.
Programmable slit helps you explore the spectral landscape for faster sample characterization-focus on fine bands with narrow setting, or if higher sensitivity is required open up the programmable slit for more light throughput. A broad slit ensures lowest baseline noise and highest chromatographic signal-to-noise. Store and report slit settings, from 1 - 16 nm, together with your raw data for GLP traceability.
Spectral storage and flexible viewing -easily overlaid spectra within a run or between runs.
Verify wavelength accuracy for GLP compliance-automatic holmium oxide filter (which can be set at the beginning of your chromatography) verifies that your wavelength is indeed what the setpoint says it is.
Agilent 1100 HPLC Hewlett Packard HP 1100 HPLC
The 1100 is based on the successful modular design of the HP 1050 systems, the new HP 1100 Series fits in a single stack, on minimal bench space. All maintenance parts are accessible from the front.
All pumps come with purge valve, connecting tubing, solvent cabinet, and solvent bottles for convenient startup.
Hewlett Packard / Agilent 1100 HPLC typical configuration:
HP 1100 HPLC System including, G