主要針對(duì)汽車(chē)空調(diào)各種漏點(diǎn),整個(gè)系統(tǒng)快速100%不會(huì)誤報(bào),10-30分鐘,100%找出各種泄漏點(diǎn),代替加壓力,灑水,熒光粉,拆系統(tǒng)在水中浸泡的原始方法。
工作原理,主要針對(duì)氟的化學(xué)成份,稀濃度,抓捕分析,在空調(diào)系統(tǒng)中追捕氟的泄漏量,氟的顆粒量少0.01的分之一,100%分析。






原理Principle
利用一個(gè)高的真空泵,將空調(diào)系統(tǒng)可能微泄的氟利昂吸入探測(cè)器,探測(cè)器采用高頻磁場(chǎng)低壓電離的工作方式,吸入微量的氟利昂,其液晶顯示數(shù)字立刻上升,同時(shí)蜂鳴器報(bào)警。
by using a high vacuum pump, the micro leak freon can to inhale detector, detector adopts low-voltage high frequency magnetic field ionization ways of working, inhaled trace of freon, the liquid crystal display Numbers rise immediately, at the same time a buzzer alarm.
技術(shù)The core features
1)持續(xù)穩(wěn)定的工作
2)能檢測(cè)0.01ppm的氟利昂,相當(dāng)于0.05克/年的泄漏量。
1) stable and reliable work;
2) the highest accuracy to detect 0.01 PPM of freon, equivalent to 0.05 g/leakage of the year.
典型效果Tical effect
1) 蒸發(fā)器檢漏,在確定漏點(diǎn)前,無(wú)須拆風(fēng)口,拆儀表盤(pán);
2) 可以檢測(cè)到老化的空調(diào)軟管滲漏(肥皂泡、熒光劑測(cè)不到的漏點(diǎn));
3) 不制冷的汽車(chē)空調(diào)系統(tǒng),不需要添加,即可檢測(cè)。
4) 看不到氣泡的氣門(mén)芯泄漏1秒鐘即可;
5) 半小時(shí)一輛車(chē),檢測(cè)完畢,無(wú)須拆系統(tǒng),無(wú)須水中浸泡;
1) the evaporator leakage, before determining leak point, do not need to diantle tuyere and tear open the dashboard;
2) can detect leakage of air conditioning hose aging (soap bubbles, fluorescent agent can't measuring leak point);
3) no refrigeration automobile air conditioning system, don't need to add freon, can detect.
4) 1 second can determined the leak valve core;
5) Half an hour to complete the detection of a car, no need to diantle the system, no water immersion;
使用介紹Method of use
蒸發(fā)箱,只要5分鐘,關(guān)閉空調(diào),把探測(cè)器放在蒸發(fā)箱下面的風(fēng)口,數(shù)字上升3-10左右,確定有漏。
the evaporation box: Five minutes is enough. Turn off the AC, and put the probe in tuyere on the bottom of the evaporation tank, figure up 3-10 or so, determine how leakage
在確定漏點(diǎn)前,無(wú)需拆風(fēng)口before determined the leak point, with no need to open panel
壓縮機(jī):只要5分鐘,探頭在機(jī)體,軸頭來(lái)回3-5次,數(shù)字上升5-15左右,確定有漏。
the compressor: Five minutes is enough.. Place the probe in the body and turn the head back and forth 3-5 times, and if the number rises by 5-15,then the leak is determined.
冷卻箱,10分鐘,把探頭隨著箱體結(jié)構(gòu)來(lái)回均勻探測(cè)移動(dòng),數(shù)字上升,3-30左右,確定有漏。
the cooling tank: It takes about ten minutes. Move the probe with the body structure of the cooling tank at steady pace, and if the number rises by 3-30, then the leak is determined.
剩余管道的接頭處10分鐘把探頭隨管道走向來(lái)回3-5次,數(shù)字上升5-30左右,確定有漏。
the remaining of pipe joint: This step takes around ten minutes. Move the probe along the pipeline back and forth 3-5 times, and if the number rises by 5-50, then the leak is determined.