標準型安全光幕由于具有很強的信號發射和接受能力,因此C2000標準型安全光幕即使在惡劣的工業條件亦可可靠運行。
該裝置可實時現實功能和狀態信息的功能使得快速進行試運行成為可能,并可減少機械不必要的停車次數。
由于該裝置采用組合式的設計概念,可使裝置特性與具體應用要求達到匹配,
因此在確保機械安全性的同時也大大提高了投資的經濟型。
完備的接口和服務理念使得該產品組可為該產品組可為該領域提供理想的解決方案。
檢測高度:750MM
檢測:20MM
檢測距離:1-6M
| Functions-Sender | |
| Beam coding: | Yes |
| Configuration method: | hard wired |
| Extension connection: | - |
| Safe device communication via EFI/SDL: | - |
| Functions-Receiver | |
| Restart interlock: | - |
| external device monitoring: | Yes |
| Beam coding: | Yes |
| Muting with: | Flexi Classic, Flexi Soft |
| Configuration method: | hard wired |
| Extension connection: | - |
| Safe device communication via EFI/SDL: | - |
| Technical Data-Sender | |
| Protective field height: | 750 mm |
| Resolution: | 30 mm |
| Scanning range from ... to: | 0 ... 6 m |
| Housing cross section: | 34 x 29 mm |
| Type: | Type 2 (IEC 61496) |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) |
| Category: | Category 2 (EN ISO 13849) |
| Test rate (internal test): | 13 /s (EN ISO 13849) |
| Maximum demand rate: | 8 /min (EN ISO 13849), between two demands on a safety-related response of the device at least 100 internal or external tests must be carried out. |
| Performance Level: | PL d (EN ISO 13849) |
| PFHd: | 2,2 * 1E-08 |
| TM (Mission Time): | 20 a |
| Enclosure rating: | IP 65 (EN 60529) |
| Protection class: | III |
| Ambient operating temperature from ... to: | 0 ... 55 °C |
| Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
| Oscillation frequency from ... to: | 10 ... 55 Hz |
| Shock resistance: | 10 g, 16 ms, IEC 68-2-29 |
| Weight: | 0.78 kg |
| Supply voltage typical, from, to: | 24 V DC, 19,2 V DC, 28,8 V DC |
| Maximum power consumption: | 6.2 W |
| Wave length: | 950 nm |
| Connection type: | Plug |
| Maximum connection cable cross-section: | 0.25 mm2 |
| Technical Data-Receiver | |
| Protective field height: | 750 mm |
| Resolution: | 30 mm |
| Housing cross section: | 34 x 29 mm |
| Type: | Type 2 (IEC 61496) |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) |
| Category: | Category 2 (EN ISO 13849) |
| Test rate (internal test): | 13 /s (EN ISO 13849) |
| Maximum demand rate: | 8 /min (EN ISO 13849), between two demands on a safety-related response of the device at least 100 internal or external tests must be carried out. |
| Performance Level: | PL d (EN ISO 13849) |
| PFHd: | 2,2 * 1E-08 |
| TM (Mission Time): | 20 a |
| Enclosure rating: | IP 65 (EN 60529) |
| Protection class: | III |
| Ambient operating temperature from ... to: | 0 ... 55 °C |
| Vibration resistance (checked to): | 5 g (IEC 68-2-6) |
| Oscillation frequency from ... to: | 10 ... 55 Hz |
| Shock resistance: | 10 g, 16 ms, IEC 68-2-29 |
| Weight: | 0.78 kg |
| Response time: | 12,5 ms |
| Supply voltage typical, from, to: | 24 V DC, 19,2 V DC, 28,8 V DC |
| Maximum power consumption: | 8 W |
| Maximum switching voltage: | Vs-2.25 V |
| Maximum switching current: | 500 mA |
| Wave length: | 950 nm |
| Connection type: | Plug |
| Maximum connection cable cross-section: | 0.25 mm2 |