干式活塞流量校準器Defender 520M 50-5000ml/min
流量校準器Defender 510/520/530 儀器介紹:
Defender 510/520/530是新一代的干式氣體流量計,它是流量計,并被眾多的個體采樣泵廠商推薦和配套使用。可用于工業衛生、領域和各類實驗室。它采用干式活塞運動的原理,按鍵即可產生連續多個讀數。與傳統的泡沫式流量計相比,使用更加方便快速。520型號比510增加了同時測試溫度和壓力的功能。
流量校準器Defender 510/520/530 主要特點:
- 采用干式活塞原理,使用簡單方便
- 流量控制,經過ISO17025
- 結構緊湊
- 寬大顯示屏幕
- 每組讀數100個
- 可內置溫度、壓力傳感器,優化測試結果(520系列)
| 型號 | Defender 510 | Defender 520 | Defender 530 | ||
| 流量范圍 | 510L, 5-500ml/min 510M, 50-5000ml/min 510H, 300-30,000ml/min | 520L, 5-500ml/min 520M, 50-5000ml/min 520H, 300-30,000ml/min | 530L, 5-500ml/min 530M, 50-5000ml/min 530H, 300-30,000ml/min | ||
| 流量 | 1% | 1% | 1% | ||
| 標準的 | N/A | N/A | 1.2% | ||
| 可選 測量 單位 | 流量 | mL/min, L/min, cc/min, cf/min | mL/min, L/min, cc/min, cf/min | mL/min, L/min, cc/min, cf/min | |
| 標準化 | N/A | N/A | L/min, sL/min, scc/min, scf/min | ||
| 溫度 | N/A | ℃ ℉ | ℃ ℉ | ||
| 壓力 | N/A | mmHg, PSI, kPa | mmHg, PSI, kPa | ||
| 溫度和壓力傳感器 | No | Yes | Yes | ||
| 壓力 | N/A | 3.5 mmHg (典型) 7.0 mm () | 3.5 mmHg (典型) 7.0 mm () | ||
| 溫度 | N/A | 0.8℃ (典型) 1.3℃ () | 0.8℃ (典型) 1.3℃ () | ||
| 每次讀數時間 | 1~15 秒 | ||||
| 讀數模式 (選擇從1到100次測量的平均值) | 單次 (手動), 連續或突發模式 | ||||
| 氣體兼容性 | 吳腐蝕性氣體、不結露氣體, 濕度小于70% | ||||
| 流動模式 | 或抽吸 | ||||
| 測量單元 | 一體式 | ||||
| AC 交流直流變換器/充電器 | 12V DC, > 250ma, 2.5mm中心位置 | ||||
| Battery System電池類型 | 6V 可充電密封鉛酸蓄電池,典型工作時間6~8 小時 | ||||
| 電池運行時間 (5 次/分鐘) | 背景光打開3小時, 背景光關閉 8小時 | ||||
| 壓入或抽吸附件 | 軟管 | ||||
| 操作壓力 () | 15 PSI | ||||
| 顯示 | 帶背光的圖形LCD液晶顯示器 | ||||
| 數據端口 (使用優化軟件) | RS-232串口 | ||||
| 數據電纜 (使用優化軟件) | 1 米 Defender校準器至電腦的串口 | ||||
| 護箱 | 軟質或硬質儀器箱 | ||||
| 尺寸(H x W x D) | 5.5”x6”x3”/140x150x75mm | ||||
| 重量 | 29oz/820g | ||||
| 服從:RoHS-和CE | |||||
流量校準器Defender 510/520 采購信息:
- Bios Defender 510L Low Flow 5-500ml/min
- Bios Defender 510M Medium Flow 50-5000ml/min
- Bios Defender 510H High Flow 300-30000ml/min
- Bios Defender 520L Low Flow 5-500ml/min
- Bios Defender 520M Medium Flow 50-5000ml/min
- Bios Defender 520H High Flow 300-30000ml/min
流量校準器Defender 510/520 技術參數:
| Flow Ranges | Low(L)5 mL–500 mL/minMedium(M)50 mL–5,000 mL/minHigh(H)300 mL–30,000 mL/min |
| Accuracy | 1%Volumetric |
| Size | all enough to fit easily in your hand;slim enough to slide into a briefcase or tote |
| Weight | 29 oz/820 g |
| Dimensions(H x W x D) | 5.5 x 6 x 3 in/140 x 150 x 75 mm |
| User-Seleable Measurement Units | |
| Volumetric Flow | mL/min L/min cc/min cf/min |
| Pressure(Defender 520 only) | mmHg PSI kPa |
| Temperature(Defender 520 only) | ℃℉ |
| Defender 500 Series Specifications | |
| Approximate Time per Reading | 1–15 seconds |
| Gas Compatibility | Use with non-corrosive,non-condensing,non-combustible gases,less than 70%humidit |
| Flow Modes | Suion or Pressure |
| Measurement Cell Style | Integrated |
| Temperature and Pressure Sensors | In the flow streamPress.:3.5 mmHg(tical),7.0 mm(max);Temp.:0.8°C(tical),1.3°C(max) |
| Reading Styles | Single(manual),Continuous or Burst,with averaging funion user-seleablefrom 1 to 100 measurements |
| AC Adapter/Charger | 12V DC,>250ma,2.5 mm,center positive |
| Battery System | 6V rechargeable,sealed lead-acid,6–8 hrs tical operation |
| Battery Operational Time(5 cycles/min) | 3 hrs backlight on,8 hrs backlight off |
| Pressure and Suion Fittings | 1/4"ID Hose Barb |
| Warranty | 1 year;battery 6 months |
| Storage Temperature | 0-70℃ |
| Ambient Humidity | 0-70%,non-condensing |
| Operating Pressure(Absolute) | 15 PSI |
| Display | Backlit graphical LCD |
| Data Port(for use with Optimizer software) | Serial (RS-232) |
| Data Cable(for use with Optimizer software) | 1 meter(Defender Data Port to PC serial port) |
| Proteive Case | Soft side or Pelican case available |
| RoHS-and CE-compliant | |