本規格書適用于RTI-10 SERI FUSE系列保險絲。 This Specification apply for RTI-10 seri fuse. 2.適用文件(Apply the standard): 2.1合IEC60127/UL248標準。(ApplyIEC60127 and UL248standards) 2.2標識(Approval marking):
4.材料(Material):
| |||||||||||||||||||||||||
4.1玻璃管Gl tube(陶瓷管Cermic tube) 玻璃管或陶瓷管須陷、缺損、凹陷,明顯臟污。(The gl tube should be of no blemish, no damage and no pollution.) 4.2銅帽(Copper cap) 每個銅帽須焊接牢固,導電性良好,表面鍍層結合牢固,不易脫落,傷。浸入溫度為15-35℃的水中24小時,按標準的要求施加軸向拉力5N,并持續1分鐘,不會出現松動、松脫的情況。(Every copper cap must be welded tightly and have good electric conductivity. Also the outer coating can be very tight, and not easily fallen off. It can be immersed in water with temperature between 15-35℃for 24 hours. Every copper cap can stand axial pulling force 5N exercised by special equipment for minute.) 4.3焊錫(solder) 焊料應具有良好的電接觸性能,并且在正常使用時不應有熔化的跡象。(The welding materials should have good electric conductivity and not be melted at normal using.) 4.4引線(Lead tail) 引線采用鍍錫銅線,具有良好的可焊性能,導電性能。可焊性合GB2423.28-82 /IEC68-2-20之標準。引線的尺寸以及形狀可以根據客戶的不同要求制作。(Lead should be tinned and have the performance of welding and good contact with electricity.Jionting performance apply for GB2423.28-82/IEC68-2-20 standard) 5.電氣性能(Electricity function) 5.1測試具備的環境條件如下(The environment condition of the tt):
| |||||||||||||||||||||||||
5.2測試儀器具備的條件如下(The requirement of the tting equipment):
C.并應使用合標準的測試制具來安裝保險絲。(The tt fixtur must meet IEC60127 standard.) 5.3時間/電流測試(Time/electrical characteristics tt) 對保險絲通以2.1倍的額定電流時,保險絲應該在120 s之內動作;通以2.75倍的額定電流時,保險絲應該在0.4 s~10 s之內動作;通以4倍的額定電流時,保險絲應該在150ms~3s之內動作;通以10倍的額定電流時,保險絲應該在20ms~150ms之內動作;并且已動作的保險絲不會出現再導通損壞的情況。 Fuse shall open in not more than 120s at 210%of rated current ;Fuse shall open in not ls than 0.4 s or morn than 10 s at 275% of rated current; Fuse shall not open in not ls than 150ms or morn than 3 s at 400% of rated current; Fuse shall open in not ls than 20ms or more than 150ms o at 1000% of rated current .The opened fuse shall be no tracking or re-tablishment of the circult.
| |||||||||||||||||||||||||
5.4耐久性試驗(Endurance tt) 對保險絲通過1.0In電流1小時,然后斷電15分鐘,此為一個循環,如此經過100次循環后,再對保險絲通以1.5In持續1小時,此測試完成后,再量保險絲兩端的電壓降,此數值不出10%的變化。并且相關數據不能出規格表中的要求。同時在測試過程中不能出現保險絲斷開的情況。 Fuse shall carry 100% of rated current continuously for1 hour.Immediately after,The current is switched off for 15 minut. This cycle is repeated 100 tim. After 100 cycl, Fuse shallcarry 150% of rated currend continuously for1 hour.Immediately after,Fuse shall carry 100% of rated currendin order to measurethe fuse voltage drop. the voltage drop shall not be deviated from the value before endurance tt by more than 10% and the value can not exceed the standard list. Meanwhile, the fuse can not open during the above tts. 規格表
| |||||||||||||||||||||||||
5.5分斷能力測試(Breaking capacity tt) 分斷能力35AOR 10In,選較大的值,相關線路應合IEC60127之相關標準。 Rated breaking capacity :35A or 10In ,whichever is greater,tted with a.c and circuit apply for IEC60127. 5.6鹽霧測試(Salt tt) 將保險絲進行4小時的鹽霧測試時,保險絲不會出現明顯變色的現象。 The fus shall remain in the humidity chamber when tting cannot be completed in a 4 hrs period. 6.標志(Marking): 6.1額定電流(rated current): 2A、3.15 A 6.2額定電壓(rated voltage): 250V 6.3標志(approval marking): UL VDE 6.4動作特性(action characteristic : T 6.5商標(trademark): LB 6.6標志(Rohs mark): 6.7分斷能力類型:L
| |||||||||||||||||||||||||